Fiber Optic Cabling & Splicing in the UAE
Fiber optic cabling, fusion splicing & OTDR testing in the UAE for backbones, data centers & campuses. Single & multimode. Request a survey.
Fiber Optic Cabling & Splicing
High-bandwidth backbones, done right. AlphaStone installs fiber optic cabling for buildings, campuses and data centers across the UAE — pulling, fusion splicing, termination and OTDR testing — single and multimode, fully certified with test reports. The backbone your network deserves.
- indoor/outdoor fiber runs
- fusion splicing
- OTDR & loss testing
- LC/SC termination & enclosures
Options we design & install
Cat6
1G, 250MHz — most offices
Cat6A
10G to 100m, 500MHz
Cat7 / 7A
Shielded, 600MHz+
Fiber (OS2/OM4)
Backbones & data centers
What the service covers
- Site survey & design
- Containment & pathways
- Cable pulling & dressing
- Termination & patching
- Fluke DSX certification
- TIA-606 labeling
- As-built documentation
- Warranty registration
Fiber types we install & splice
We select single or multimode fiber to match distance, speed and budget.
| Fiber type | Mode | Reach / speed | Best for |
|---|---|---|---|
| OS2 | Single-mode | Long-haul, 10–100G | Backbones, campus, FTTx |
| OM3 | Multimode | 10G @300m | Legacy data centers |
| OM4 | Multimode | 10G @550m · 100G @150m | Data centers |
| OM5 | Multimode (WB) | SWDM, higher density | Modern high-density DCs |
Key benefits
indoor/outdoor fiber runs
fusion splicing
OTDR & loss testing
LC/SC termination & enclosures
single & multimode.
Ready to start your project?
Free site survey and a fixed quote anywhere in the UAE.
Our delivery process
Free Site Survey
We assess your site, requirements and compliance needs.
Design & Fixed Quote
Clear scope, standards and transparent pricing.
Install & Test
Certified installation, tested and labeled, minimal downtime.
Handover & AMC
Documentation plus optional maintenance contracts.
BICSI / TIA-568 / ISO 11801
- 90m permanent link + 10m patch cords
- TIA-606 labeling & administration
- Fluke DSX channel certification
- Up to 25-year manufacturer warranty
Industries & properties we serve
Frequently asked questions
Should I use single-mode or multimode fiber?
We use multimode (OM3/OM4/OM5) for shorter, high-bandwidth links such as data-centre and inter-floor backbones, and single-mode (OS2) for longer campus and inter-building runs. We advise the right fiber type and connector per link on survey.
Do you provide OTDR test reports for fiber?
Yes — every fiber link is tested with an OTDR and optical power meter, and you receive insertion-loss and reflectance results per link plus the test traces and a labelled schedule, confirming each link is within the agreed loss budget.
Do you handle telecom and FTTH-grade fiber too?
Yes. Beyond in-building cabling we deliver operator-grade outside-plant and FTTH fiber. See our Fiber Optic Installation page.
Which cable category do I need?
Cat6 suits most offices; Cat6A supports 10G to 100m; Cat7 adds shielding; fiber is used for backbones. We advise per use.
Do you certify the cabling?
Yes. Every link is certified with a Fluke DSX analyser (channel and permanent-link testing) and handed over with full pass/fail test reports, a labelled outlet schedule and as-built drawings — documenting performance to the relevant TIA/ISO standard and supporting the warranty.
Is it BICSI and TIA compliant?
Yes — designed and installed to BICSI, TIA-568 and ISO 11801, with TIA-606 labeling.
Related services
Serving all seven emirates
Start your project with AlphaStone
Free site survey and a no-obligation, fixed quote. Prefer to talk? Call or WhatsApp +971 55 505 9256.
- Free site survey & honest advice
- Transparent, fixed pricing
- Compliant (SIRA / ADMCC / BICSI) design
- One contractor for cabling, network & security
Request your quote
We reply within one business day.